If you’ve ever struggled with a wobbly network cabinet that makes your servers shift, your cables come loose, or your IT team hesitate to walk near it—you’re not alone. As a network cabinet supplier who’s worked with small business owners, data center managers, and IT technicians for over a decade, I’ve seen firsthand how an unlevel cabinet can turn routine maintenance into a frustrating, risky chore. Today, I’m walking you through the step-by-step process to level a network cabinet properly, along with the common mistakes that cost our clients time and money, and why getting this right matters more than you might think. Network Cabinet

Why Leveling a Network Cabinet Isn’t Just a “Tiny Detail”
Before we dive into the how, let’s talk about why this step matters. A lot of first-time buyers or even installers think leveling is just something you do with a bubble level to make the cabinet look straight. But it’s so much more: it directly impacts equipment safety, cable management, ventilation, and even the lifespan of your gear.
Think about it: servers, switches, and patch panels are designed to sit evenly. If your cabinet is tilted forward, all the weight of the 1U switches at the top presses down on the front mount rails, warping them over time. Tilting to the side puts uneven stress on hard drives inside storage arrays, increasing the risk of failure during read/write operations. And if the cabinet’s base isn’t flat on the floor, air can’t circulate properly through the bottom vents—leading to overheating that forces your IT systems to throttle performance or shut down unexpectedly. We’ve had clients call us three months after installing a new cabinet because their top 10 servers were throwing fan errors, only to find the cabinet had shifted a fraction of an inch off the floor and blocked 70% of the lower ventilation path. That’s the kind of avoidable problem a quick leveling could have fixed.
What You’ll Need Before You Start
I always tell our clients to gather tools first to avoid half-finished jobs. You don’t need fancy, expensive equipment—just a few basics:
- A professional-grade bubble level: Not the tiny, $1 level from the hardware store. A 2-foot long level works best for tall cabinets, because it spans more of the surface and catches small tilts that a mini level would miss. Laser levels work too, but a standard bubble level is more than enough for most installations.
- Adjustable cabinet feet or shims: Most of our standard network cabinets come with adjustable steel feet, but if you’re installing on an uneven concrete floor (super common in old server rooms or basement setups), you’ll need shims. We recommend either rubber-shimmed steel shims (to add grip and keep the cabinet from sliding) or hardwood shims for temporary fixes—just make sure they’re thick enough to fill the gap between the cabinet base and the floor.
- A wrench or Allen key set: Almost all adjustable cabinet feet use either a ½-inch wrench or a 5mm Allen key. Double-check the foot type before you start—some of our heavy-duty 42U cabinets have larger feet, so grab the right tool to avoid stripping the threads.
- A tape measure: To double-check that the cabinet is square (not just level front-to-back or side-to-side) and that there’s equal clearance between the front and back doors.
Step 1: Prepare the Installation Site
The first mistake I see people make is placing the cabinet on the floor without prepping the space. Even if your floor looks flat to the naked eye, a quick check will show gaps. Start by clearing the area where you’ll put the cabinet—remove any boxes, cables, or debris that might hide uneven spots. Then, lay your tape measure across the floor at the spot, and check for dips or rises. If it’s a concrete floor, drag a straight edge (like a long piece of wood) across it; any gap larger than ⅛ inch is a sign you’ll need shims.
Pro tip: For raised floor data centers, the process is a little different. Raised floors are designed with pedestal tiles, so you’ll need to make sure the cabinet feet align with the top of the pedestals, not the tiles themselves. That way, the weight of the cabinet is supported by the structural pedestals, not the tile edges, which can shift under heavy loads. We always tell data center clients to mark their pedestal locations before setting the cabinet down to avoid this.
Step 2: Set the Cabinet Roughly in Place
Don’t line it up perfectly yet—set it down loosely, leaving a little space to adjust the feet. For freestanding cabinets, lift the back legs slightly and slide shims under them if you already see a tilt, but don’t tighten anything down. For cabinets that will be bolted to the floor, hold off on drilling until you’re sure the cabinet is level. I know it’s tempting to get it placed fast, but rushing here will mean you have to reposition the cabinet multiple times, which is a pain with 300lb-400lb 42U cabinets.
Another thing: if you’re installing multiple side-by-side cabinets, level one first, then use it as a reference for the next ones. If they’re even slightly out of level with each other, the cable management bars and overhead raceways won’t line up, making it harder to run cables neatly. We once had a client who installed three cabinets next to each other, and the middle one was ¼ inch lower than the other two—their cable tray sat lopsided, so every cable run ended up pinched or stretched. That’s a $20 fix (shims) that turned into hours of rework.
Step 3: Level the Cabinet Side-to-Side First
Start with the level on the cabinet’s vertical side rails (the left and right sides of the frame, not the doors). If the bubble is off, adjust the two side feet—either raise or lower them until the bubble sits exactly in the center. For each foot, turn the adjustment bolt a quarter turn at a time; big turns can make the cabinet lurch and throw your reading off.
Once the side-to-side level is good, double-check with the level placed on the cabinet’s top surface. Wait—yes, the top surface. The top of your cabinet needs to be level too, because if it’s tilted, any equipment mounted on top (like a fiber patch panel or battery backup unit) will be unbalanced. I’ve seen a 100lb UPS slide off the top of a slightly tilted cabinet because the owner only checked the sides, not the top. Don’t skip that step.
Step 4: Level Front-to-Back, Then Re-Check
Next, move the level to the front edge of the cabinet’s frame. If the front is lower than the back, adjust the front feet upward; if the back is lower, adjust the back feet. Again, make small, incremental turns. Once the front-to-back level looks good, go back and re-check the side-to-side level—adjusting one set of feet can throw the other off, so you need to iterate back and forth. Do this at least two times, and each time, check both side-to-side and front-to-back. A good rule of thumb: if the bubble stays centered even after you set the level down and pick it back up, it’s properly leveled.
Step 5: Fill Gaps with Shims (If Needed)
If you have gaps larger than ⅛ inch between the cabinet base and the floor, you’ll need shims here. Don’t overstuff—just place shims snugly against the base and the floor, under the feet. If you put a thick shim under one foot, make sure it’s centered so the weight of the cabinet doesn’t cause it to shift. For concrete floors, we prefer rubber shims because they absorb small vibrations, which is great for server rooms where even tiny vibrations can affect hard drive reliability.
A quick warning: never use thin cardboard or paper as a shim. They compress over time, and your cabinet will go back to being unlevel within a few months. We get a lot of returns for “wobbly cabinets” that turn out to be shims that crumbled, so stick to steel or rubber shims for permanent setups.
Step 6: Secure the Cabinet (Optional, But Recommended)
If your cabinet is near a door, in a high-traffic area, or has heavy equipment inside, bolt it to the floor. This is an extra step that prevents the cabinet from tipping over—something that’s not just a hassle, but a safety hazard. To do this, first make sure the cabinet is still level after re-adjusting the feet. Then, mark the floor through the pre-drilled holes in the cabinet’s base, drill anchor bolts, and secure the cabinet. Tighten the bolts just enough to hold it, but don’t over-tighten—you don’t want to warp the base of the cabinet.
Common Mistakes to Avoid
I’ve made almost every single one of these mistakes myself early on in my career, so trust me when I say these are worth skipping:
- Only checking one axis: A cabinet can be level side-to-side but tilted front-to-back, and vice versa. Always check both, and double-check after each adjustment.
- Ignoring the base not the frame: Some cabinets have doors that are slightly out of alignment, but the frame is the important part for equipment mounting. Don’t fix the doors and skip the frame level.
- Not accounting for the floor’s slope: If your floor slopes even a little, don’t assume the cabinet’s feet will fix it. You might need shims under multiple feet, not just one or two.
- Rushing the final check: After you think you’re done, wait 10 minutes, then go back and check the level again. Sometimes the cabinet will settle a little on the shims or feet, so a final check prevents having to re-do the whole thing later.
What If You’re Working with a Pre-Assembled Cabinet vs. a Flat-Pack?
Most of our network cabinets come pre-assembled, but we also sell flat-pack options for clients who need to ship them long-distance or store them before installation. The leveling process is almost the same, but for flat-pack cabinets, make sure you tighten the frame bolts first before adjusting the feet. If you adjust the feet before tightening the frame, you’ll end up with a loose frame that won’t stay level.
Another note: for tall cabinets (42U and above), always have two people when moving and leveling them. These cabinets are heavy, and trying to adjust them alone can lead to injury or dropping the cabinet on your level (which breaks it—another cost we see all the time).
Final Thoughts
Leveling a network cabinet might seem like a tiny, boring step in a big IT setup, but it’s the foundation of keeping your equipment safe, your systems running smoothly, and your IT team happy. I’ve seen clients who skipped this step spend thousands on hardware repairs because servers warped from uneven pressure, or waste hours re-patching cables that came loose from a tilted cabinet. It’s a 15-minute job that saves you so much time, money, and stress down the line.

If you’re shopping for a new network cabinet and need help picking the right one for your space, or if you have questions about leveling your existing setup, feel free to reach out to our team to discuss your needs. We’re here to make sure your cabinet works as hard as you do.
Fiber Optic Accessories References:
Server Rack and Cabinet Installation Best Practices, Telecommunications Industry Association (TIA-569-B)
Data Center Environmental Guidelines, American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE)
IT Equipment Safety Standards, International Electrotechnical Commission (IEC 60297)